Koehler Instrument K43002 / K43092 Dual-Twin Foaming Characteristics Apparatus

Condition: New Brand new item from stock or on order from manufacturer
1 YEAR MANUFACTURER'S WARRANTY
Stock #:
N1179
Dimensions (approx.):
32.25"W x 15"D x 31.25"H (outside)
Electrical:
specify 115 or 230 Volts, 50/60 Hz,
Product Description
Foaming of lubricating oils in applications involving turbulence, high speed gearing or high volume pumping can cause inadequate lubrication, cavitation, overflow and premature oxidation. The sample is blown with a controlled volume of air at different specified temperatures, including a newer high temperature test at 150°C. The resultant foam is measured at the end of each aeration period and at different intervals afterward. In the high temperature test, the amount of time required for the foam to collapse to '0' after the aeration period is also measured.

Features and Benefits
~ Dual-twin models for standard foaming characteristics tests
~ High temperature liquid baths for `Sequence IV' tests
~ Automatic time sequence models for both tests
~ Custom configurations for specialized applications

Performs two tests at 75°F (24°C) and two tests at 200°F (93.5°C). Consists of two 12x18 in. (30.5x45.7cm) constant temperature baths with 1000mL test cylinders, certified diffusers, air delivery tubes, and flowmeters (94mL/min.) for each sample. Baths are equipped with microprocessor temperature controls, copper immersion heaters and 1/20hp circulation stirrers to maintain temperature uniformity of ±1°F (±0.5°C). Microprocessor PID control provides quick temperature stabilization without overshoot and the bath is protected by an overtemperature control circuit that interrupts power should bath temperature exceed a programmed cut-off point. Dual LED displays provide actual and setpoint temperature values in °C/°F format. Test cylinders are held securely in place by quick-locking cams in the bath cover assembly. A separate stainless steel support rack is provided to hold the test cylinders after removal from the bath. Cold bath (24°C) has built-in coils for circulating exit air from the high temperature test cylinders prior to passing to a volume meter, and a separate coil for circulating cooling water or refrigerant when the ambient temperature exceeds the test temperature. Supplied with rubber stoppers and glass air outlet tubes for each cylinder. Bath controls are enclosed in a finished steel base with chemical resistant polyurethane enamel finish. Communications software (RS232, etc.), ramp-to-set and other enhanced features are available as extra cost options. Contact Labequip, your authorized Koehler representative for information.

FTM 791-3213 Aircraft Lubricants Test
Employs more severe conditions - smaller sample, increased air flow, longer aeration period - to test the foaming characteristics of aircraft-turbine lubricants. All models are available on special order for FTM 791-3213 testing. Please contact us for specifications and ordering information.

Air Flow Rate: 94mL/min
Bath Temperature: 24°C (75°F) and 93.5°C (200°F) - Operator Variable
Bath Capacity: 9 gal (38.5L) each bath
Temperature Control:
Digital Setpoint and Displays °C/°F switchable
Built-in Overtemperature Cut-off Protection

**** REQUEST PRICING ON UNIT WITH AUTOMATIC TIME SEQUENCING AND SOFTWARE
The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Koehler K43002/K43092 Dual-Twin Foaming Characteristics or copy the following into your browser address window: labequip.ca/stock/pictures/n1179.pdf
Made in USA.

ACCESSORIES:

COMES COMPLETE WITH:
Test Cylinders, 1000mL (4)
Diffuser Stones, calibrated and certified (4)
Air Delivery Tube Assemblies (4)
Air Outlet Tubes (4)
Rubber Stoppers (4)
Bath Jars (2)
Support Rack (1)
Acrylic Safety Shield, 18"

OPTIONAL ACCESSORIES AVAILABLE AT ADDITIONAL COST:
387-115-001 Air Pump
K43025 Diffuser Stone Test Apparatus
250-000-12F ASTM 12F Thermometer (or 250-000-12C ASTM 12C Thermometer)
K43026 Wet Test Gas Meter (not required for Alternative Procedure)
332-005-005 Drying Tower
K33031 Refrigerated Recirculator - Use with foam test baths for 24°C tests (Sequence I and III). Microprocessor based digital control and quiet running compressor provide reliable operation and accurate control within ±0.5°C. For complete specifications, please contact Koehler Customer Service. 115V 60Hz, 8A
K33032 Refrigerated Recirculator
250-000-12C ASTM 12C Thermometer.Range:-20 to +102°C
344-100-01C Certified Diffuser Stone. Calibrated and certified for compliance with ASTM specifications for pore diameter and permeability
344-100-001 Diffuser Stone, non-calibrated
344-005-001 Stainless Steel `Mott' Diffuser
344-005-01C Stainless Steel `Mott' Diffuser Certified